Learning, Conditioning, Reward
Startle Reflex System
Startle Reflex System
Startle Reflex System

Startle Reflex System

Prepulse inhibition (PPI) is the phenomenon in which a weak prepulse stimulus attenuates the response to a subsequent startling stimulus. The stimuli are usually acoustic, light and tactile stimuli. Patients with schizophrenia and some other neuropsychiatric disorders have impaired PPI.Science’s Rodent Startle Reflex System allows for Pre-pulse inhibition and fear-potentiated startle protocols efficiently and economically. Animal models are widely used to test hopotheses linking genetic components of various diseases.

FeaturesSpecificationHow to orderReference
Features

Features

• Applicable for Rats and Mice, maximum 16 chambers.

• Adopts user-friendly graphical interface settings, experiment building and modification can be achieved by clicking the icon or picture directly. 

• Sound, light, electricity and tactile stimuli occur simultaneously or in serial, and can be freely combined. Available for Habituation, Pre-pulse Inhibition(PPI), Potentiated Startle or user-defined experiments.


Specification

Sound

• Speaker: Raise and lower volume based on intrachamber volume (from the detector), 

• AI detection, real time sound intensity display.

• White Noise Generator included in default Software, include WhiteNoise and NWhiteNoise.

• Specify the duration of time and Hz of white noise, duration 1~10000ms, Max 130db.

• Pure sound stimulus: duration time 1~ 10000ms, frequency range 31~18000Hz, Max 130db. intensity can be set by software.

Shock Grid

• 0.1-4.0mA in 0.1mA steps

• AC Current. Alternating pulse current ensure fully shock.

• Removable Grid.

• Frequency: 1000Hz, 1ms per time.

• Full digital control, scramble-frequency constant electrical stimulator makes it no rule in animal side.

Tactile stimulation

• The intensity of stimulation can be adjusted by adjusting the pressure of the compressed gas cylinder.

Software

• Independent signal detection control in each box to precise detect the signal in the experiment.

• Independent software operated for separated channel.

• Data transmission by 100M Ethernet through experiment chamber to PC, which ensure high reliability.

• Data can be exported to .csv/.doc format for further analysis.


How to order

Ordering Information

           Item No.                                            Product
             SA217                     Startle Reflex System                                    


Reference

Reference

Zhejiang University Startle 合并